MODAVISResearch & Development MODAVIS Navigator (opens in a new tab)
Method

Describe time, space and acoustic response

An audio file becomes scientific evidence through its relationships: to an instrument state, a clock, a measurement position, a room and a processing history.

Make audio relationships explicit through timebase mappings, coordinate frames and source–receiver conditions. See how the VAO profiles describe synchronized resources, spatial positions and acoustic responses without implying that every client can execute them.

Takeaway. A sound or position becomes interpretable through its reference frame, conditions, exact resource and supported capabilities.

Worked example: How do we identify a passage within a recording?

A shared timeline needs an explicit mapping

Audio frames, video frames, MIDI events and animation ticks do not automatically share a clock. VAO 0.6.0 describes explicit timebases and mappings. Rational rates avoid ambiguous decimal approximations; half-open intervals include their start and exclude their end. A region from frame 0 to frame 48,000 at 48,000 frames per second is therefore one second long, without counting an extra endpoint sample.

A linear mapping relates coordinates as target = source × scale + offset. Both coordinate units matter. For a source measured in audio frames and a target measured in seconds, the scale has units of seconds per frame. Clock drift, residual uncertainty and discontinuities require their own treatment. A single offset can align an onset without explaining drift during a long session, and a mapping must not interpolate across an unmodeled dropout.

Technical detail. Illustrative timing calculation · explanatory notation, not a VAO JSON record

source coordinate: audio frame index at 48,000 frames/second
target coordinate: video time in seconds
scale = 1 / 48,000 seconds/frame
offset = 0.125 seconds
frame 96,000 maps to 2.125 seconds

Keep the measured alignment uncertainty and any discontinuities separately.

How do we identify a passage within a recording?

A timebase defines how positions correspond to time. A half-open interval includes its first position and excludes its end, avoiding an extra sample at a shared boundary.

Case. Cuntz

Evidence. Illustrative scenario

For a teaching calculation, take a hypothetical 192,000-frame-per-second audio realization, matching the sampling rate described for the Cuntz thesis recording setup. The excerpt below is illustrative, not an identified take.

  1. State the region in frames. The interval [192000, 384000) starts one second into the signal and spans 192,000 frames: exactly one second at the stated rate.
  2. Keep channels distinct. A stereo frame includes a sample from each channel. The same one-second interval does not become two seconds because there are two channels, nor does it become two independent pipe recordings.
  3. Connect timing systems explicitly. If a video or control timeline starts elsewhere, record a mapping between its timebase and the audio frame positions, including offset and any uncertainty or discontinuity.

Identify a passage within one fixed signal

The interval is a conceptual example. It is not an invented Cuntz audio excerpt.

Relationship Description
Signal identity One recording Changing the signal changes the coordinate reference. · bind a region
Frame interval [start, end) Start included; exclusive end excluded. · interpret in context
Interpretation A bounded passage Use its sample clock, channels and provenance.

Takeaway. An exact excerpt needs the signal realization, channel interpretation, frame interval and rate.

Limit. This numerical example is a teaching calculation, not a new analysis of a published Cuntz audio excerpt.

  • Dominik Ukolov · Musikinstrumente im virtuellen Raum (2026) · Submitted dissertation, 11 September 2026; §§8.2.2.1 and 8.4.1, printed pp. 264–265 and 275–276. The historical description and digital inventory require a resolved mapping; the manuscript is not redistributed here.
  • VAO 0.5.0 · archived Cuntz contract · The fixed Cuntz content release 0.5.0-rc.2 declares formatVersion 0.5.0. Its exact records remain historical evidence; current authoring guidance uses VAO 0.6.0.

A position means something within a frame

A coordinate triple is incomplete without units, axis definitions, handedness and a reference frame. A microphone pose in an instrument frame differs from its pose in a room frame. A geographic longitude and latitude pair must not be silently interpreted as local Cartesian x and y. Explicit transformations and their provenance let another client reconstruct the intended relations or identify a missing conversion.

For a measured response, preserve the source and receiver positions, orientations where relevant, instrument and room state, and the method used to establish them. An approximate position should remain approximate. Giving more decimal places to an estimated coordinate does not improve the underlying measurement. A change of coordinate frame is a transformation; it is not a new acoustic observation.

Can we measure the original organ by rotating its model?

A coordinate frame defines axes, orientation and units. A verified physical scale additionally requires evidence linking those coordinates to the physical object.

Case. Cuntz

Evidence. Released record

The released model declares a right-handed, Y-up frame with metre units, while its purpose limitation says the source scale has not been verified by a physical survey.

  1. Read the coordinate convention. The convention tells a renderer how to interpret model coordinates and orient the scene. It helps two applications agree about the same geometry.
  2. Read the qualification. A declared metre unit does not supply a missing calibration. If the original geometry scale was not verified, a distance computed from its vertices must not be advertised as a measured organ dimension.
  3. Use appropriate evidence for dimensions. For a documented pipe quantity, inspect the identified measurement observation and workbook source. Use the model to locate and discuss shapes within its stated limitations.

A model unit is not automatically a millimetre

The Cuntz display model has not been independently calibrated for physical measurement.

Relationship Description
Model coordinates Scene geometry A viewer can rotate and zoom the representation.
Physical measurement Calibrated dimensions Needs a documented unit, frame and calibration.

Takeaway. Coordinate consistency allows interchange; metrological validity requires additional evidence.

Limit. The notebook deliberately provides viewing controls without a physical measurement ruler.

  • Cuntz Positiv · VAO 0.5.0-rc.2 · Published manifest: identities, measurement observations, realization digests, profiles and rights. Exact examples checked against this release.
  • VAO 0.5.0 · archived Cuntz contract · The fixed Cuntz content release 0.5.0-rc.2 declares formatVersion 0.5.0. Its exact records remain historical evidence; current authoring guidance uses VAO 0.6.0.

Keep the response and its domain together

An impulse response characterizes a specified source–receiver arrangement under particular conditions. Its association with a VAO should identify the exact signal realization, channel interpretation and the scene or measurement to which it belongs. Applying that response elsewhere is a modeling choice. A player needs an explicit policy for positions outside the measured or modeled domain, such as a declared fallback, instead of suggesting that one response captures every listening position.

Record What the reader needs What it does not establish alone
Captured response Measurement setup, positions, signal identity and processing lineage. Validity at every source and receiver position.
Simulated response Geometry, material and boundary assumptions, method and evaluation evidence. A measured response of the historical room.
Acoustic metric Quantity, unit, band axes, method, uncertainty and any cited standard edition. Conformance merely because a standard is named.
Learned field or surrogate Training and validation evidence, supported domain and derivation. Reliable extrapolation to undocumented conditions.

What would it mean to hear Cuntz in another room?

Auralization makes a modeled acoustic situation audible. An impulse response describes how a sound travels from a specified source position to a specified receiver under stated conditions.

Case. Cuntz

Evidence. Illustrative scenario

Imagine presenting a Cuntz recording as if heard in another room. This is a teaching scenario; no measured response for that proposed room is supplied by this notebook.

  1. Identify the starting signal. Record the exact audio realization and its capture conditions. A microphone recording already includes effects of its original room and recording chain.
  2. Identify the proposed room response. A measured or simulated impulse response has a source position, receiver position and method. Applying it through convolution combines the signal with that response over time; it does not erase the original recording conditions.
  3. State the supported claim. The resulting sound demonstrates the chosen signal-processing arrangement. A claim about the instrument in a historical room would also require appropriate source, spatial and acoustic evidence.

A listening simulation connects several models

This is an illustrative auralization workflow, not a newly validated Cuntz listening study.

Relationship Description
Source signal A documented input Which signal or source model is used? · combine under a defined method
Room response A scoped acoustic model Which space, positions and conditions apply? · render and evaluate
Rendered sound A simulation result Retain processing parameters and limits.

Takeaway. Making an acoustic scenario audible is different from demonstrating that the historical scenario sounded that way.

Limit. The Cuntz 3D preview does not implement auralization, and this example does not add an Acoustics profile declaration to the published package.

  • Cuntz Positiv · VAO 0.5.0-rc.2 · Published manifest: identities, measurement observations, realization digests, profiles and rights. Exact examples checked against this release.
  • VAO 0.5.0 · archived Cuntz contract · The fixed Cuntz content release 0.5.0-rc.2 declares formatVersion 0.5.0. Its exact records remain historical evidence; current authoring guidance uses VAO 0.6.0.

Declare the capabilities the object actually uses

VAO 0.6.0 requires Core and Dynamic Delivery for every conforming object, including an embedded-only package. Additional profiles follow the represented capabilities: Multimodal Timeline for timebases and synchronized tracks, Spatial for frames and poses, Acoustics for relevant response or scene records, and Scientific for scientific records. Physical Instrument, Playable and Deterministic Runtime address further aspects when present. Profile declarations are not a promise that every client will execute every feature.

A useful inspection sequence is to read the profile declarations, identify required materialization groups, verify their availability, and then check the application’s implementation scope. A Blender importer may inspect a spatial package and load geometry without executing its acoustic behavior. A runtime capable of convolution still needs the correct responses, mappings and dependencies. The object contract and the application capability are both necessary to interpret what the user hears.

Does showing the organ in 3D mean the VAO is playable?

A profile names a set of requirements for a capability. A client’s support describes what an application can do with the object; the two declarations must be compared.

Case. Cuntz

Evidence. Released record

The archived Cuntz content release 0.5.0-rc.2 declares Core, Dynamic Delivery, Playable, Physical Instrument, Scientific, Multimodal, Spatial and Zenodo Repository profiles under VAO 0.5.0. This fixed example retains its original contract; new packages in this guide use VAO 0.6.0.

  1. Read the object’s declarations. The object contains information for several uses, including physical topology, scientific observations and sampled interaction. These requirements describe the package contract.
  2. State the viewer’s operation. The notebook loads a GLB display derivative and provides camera controls. It does not import the full VAO manifest, evaluate its scientific records or execute its keyboard and stop behavior.
  3. Choose another client when the task changes. To test sampled playback or synchronized controls, choose a client whose documented version supports the relevant format, profiles and resources. Record the tested operation separately from successful visual loading.

Displaying geometry and playing sound need different support

This notebook viewer displays a model. It does not claim to play the Cuntz organ or implement a VAO runtime.

Relationship Description
Visual inspection Model preview A GLB renderer lets you inspect geometry.
Playable experience Declared runtime capability Needs appropriate data, profiles and an implementing client.

Takeaway. A working 3D preview proves that the chosen model can be displayed; it does not establish complete VAO conformance or playability.

Limit. No acoustics profile or calibrated acoustic response is inferred from the presence of an organ model.

  • Cuntz Positiv · VAO 0.5.0-rc.2 · Published manifest: identities, measurement observations, realization digests, profiles and rights. Exact examples checked against this release.
  • VAO 0.5.0 · archived Cuntz contract · The fixed Cuntz content release 0.5.0-rc.2 declares formatVersion 0.5.0. Its exact records remain historical evidence; current authoring guidance uses VAO 0.6.0.

A mechanical command is not yet a sound

MMIC 1.0.0 preserves native gates, impulses, latches and continuous envelopes before any MIDI export. A hole’s contact with a reader, the resulting actuator command and the duration of an audible sound answer different questions. An impulse does not supply a measured note-off. A reading model must state the geometry, clock, controls, initial state and assumptions that connect observations to output.

MIDI is an optional translation with explicit bindings and a loss or assumption report. Pitch, channel, controller, tempo and rounding choices must be reproducible. Physical recordings, simulated recordings and recordings of unknown origin remain distinct. A comparison also needs identified inputs and checkable alignment; hearing similar results alone does not validate an interpretation.

Glossary

Provenance. The documented origin and processing or editorial history of a resource or statement. It explains how a result came about.

Work through the Cuntz example

Realization. One exact byte sequence representing an asset. Different encodings or derivatives have different exact identities.

Work through the Cuntz example

Profile. A versioned set of additional requirements. A client must satisfy the declared capabilities before claiming full support for that profile.

Work through the Cuntz example

Observation. A record connecting a property and result to the thing observed, with a method and source context. A number alone leaves those relationships unspecified.

Explain the 1281 mm Cuntz observation

Sources

  • VAO Standard 0.6.0 · Normative standard, profile index, Dynamic Delivery Profile and conformance specification in the versioned release.
  • Dominik Ukolov · Musikinstrumente im virtuellen Raum (2026) · Dissertation submitted to Universität Leipzig, 11 September 2026. Chapters 5 and 6; evaluation distinctions in §8.1.1, pp. 254–256. Page numbers refer to the printed manuscript pagination. The manuscript is not distributed by this website.
  • MMIC 1.0.0 · normative application profile · VAO-owned mechanical-music vocabulary, operational model and four independently declared conformance levels.